Technology Products Applications Sustainability Resources About Insights Request Specification Partner Portal
Products/GX Mortar Series
Repair & Masonry Mortars

GX Mortar Series

Low-carbon repair mortars and masonry bed mortars combining supplementary cementitious material blending with the GX healing additive — for applications where mortar joint failure drives ongoing maintenance cost.

Masonry worker applying mortar to a brick wall repair section with a pointing trowel
Product Overview

Mortar that reseals without re-mobilization

GX Mortar Series is formulated for masonry joint repointing, concrete surface repair, and new-construction mortar bed applications. The GX healing component embedded in the mortar matrix activates on moisture re-exposure — the same seasonal wetting and freeze-thaw cycle that causes standard repointing mortar to fail within 5–10 years of installation. The self-managed re-sealing targets the mechanism of failure rather than the visible symptom of it.

Clinker replacement through calcined clay and synthetic pozzolan blending maintains adequate early compressive strength for construction productivity (targeting ASTM C270 property method compliance) while reducing the embodied CO2 per tonne relative to OPC mortar equivalents. Three grades cover the standard masonry and repair spectrum: GXM-N, GXM-S, and GXM-R.

Substrate Compatibility

Where GX Mortar applies

Application Substrate Recommended Grade Compliance Target
Masonry joint repointing Brick, CMU, natural stone GXM-S (Type S equivalent) Designed to target ASTM C270 Type S property method
New masonry bed mortar CMU, brick, architectural veneer GXM-N (Type N equivalent) Designed to target ASTM C270 Type N property method
Concrete surface repair Existing concrete ≥ 20 MPa GXM-R (repair grade) Designed to target ICRI repair mortar performance guidelines
Parapet cap & coping Masonry, concrete GXM-S Freeze-thaw durability focus — high-exposure horizontal application
Technical Specifications

Design targets — GX Mortar Series

Design targets and aspirational performance goals. Not EPD-certified. Contact Gelmedix for project-specific guidance.

Parameter GXM-N GXM-S GXM-R
28-day compressive strength target ≥ 5.2 MPa (750 psi) ≥ 12.4 MPa (1,800 psi) ≥ 20 MPa (2,900 psi)
Water retention target ≥ 75% ≥ 75% ≥ 80%
Air content target 12% max 12% max 10% max
Application temperature range 5°C – 38°C 5°C – 38°C 8°C – 38°C
Coverage rate (10 mm joint) ~3.0 kg/m² ~3.0 kg/m² ~1.8 kg/m² per mm depth
Indicative CO2 reduction vs OPC mortar ~30–35% ~30–35% ~25–30%